{"id":14357,"date":"2019-10-11T11:00:21","date_gmt":"2019-10-11T10:00:21","guid":{"rendered":"https:\/\/www.engineernewsnetwork.com\/blog\/?p=14357"},"modified":"2019-10-10T10:52:39","modified_gmt":"2019-10-10T09:52:39","slug":"lower-power-isolated-regulated-dc-dc-modules","status":"publish","type":"post","link":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/","title":{"rendered":"Lower-power isolated, regulated DC-DC modules"},"content":{"rendered":"\n<p>Power density, low weight and ease-of-use are critical considerations when designing isolated, regulated DC-DC converter systems for a broad range of robotics, UAV, rail, communications and defence\/aerospace applications.&nbsp;<\/p>\n\n\n\n<p>The new <strong><a href=\"http:\/\/www.vicorpower.com\/dc-dc\/isolated-regulated\/dcm\" target=\"_blank\" rel=\"noreferrer noopener\" aria-label=\" (opens in a new tab)\">DCM2322 ChiP family<\/a><\/strong>, a lower-power variant of the Vicor DCM3623 series, delivers on these important requirements.\u00a0<\/p>\n\n\n\n<p>Packaged in a 22 x 23 x 7mm ChiP, the new series offers engineers wide input voltage ranges of 43 \u2013154V, 14\u201372V and  \u201350V with power levels ranging from 35 to 120W and efficiencies up to 90.5%.\u00a0<\/p>\n\n\n\n<p>Vicor DCMs use high-frequency zero-voltage switching topology to achieve industry-leading thermal and electrical performance with power densities five times greater than competing DC-DC converters.&nbsp;<\/p>\n\n\n\n<p><strong>DCM2322 ChiP Family of Parts<\/strong><\/p>\n\n\n\n<p>Package Size: 22 x 23 x 7mm<\/p>\n\n\n\n<p><strong>43\u2013154V input<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>3.3V output at 40W<\/li><li>5V output at 60W<\/li><li>12V, 15V, 24V, 28V, 48V output at 120W<\/li><\/ul>\n\n\n\n<p><strong>14\u201372V input<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>3.3V output at 35W<\/li><li>5V output at 50W<\/li><li>12V, 15V, 24V, 28V, 48V output at 100W<\/li><\/ul>\n\n\n\n<p><strong>9\u201350V input<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>12V, 15V, 24V, 28V and 48V output at 60W.<\/li><\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Power density, low weight and ease-of-use are critical considerations when designing isolated, regulated DC-DC converter systems for a broad range of robotics, UAV, rail, communications and defence\/aerospace applications.&nbsp; The new DCM2322 ChiP family, a lower-power variant of the Vicor DCM3623 series, delivers on these important requirements.\u00a0 Packaged in a 22 x 23 x 7mm ChiP, &hellip;<\/p>\n","protected":false},"author":1,"featured_media":14358,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[104],"tags":[7279,7278,7280,1923],"class_list":["post-14357","post","type-post","status-publish","format-standard","has-post-thumbnail","","category-electronics","tag-dcm2322","tag-isolated","tag-regulated-dc-dc-modules","tag-vicor"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Lower-power isolated, regulated DC-DC modules - Engineer News Network<\/title>\n<meta name=\"description\" content=\"Power density, low weight and ease-of-use are critical considerations when designing isolated, regulated DC-DC converter systems for a broad range of robotics, UAV, rail, communications and defence\/aerospace applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lower-power isolated, regulated DC-DC modules - Engineer News Network\" \/>\n<meta property=\"og:description\" content=\"Power density, low weight and ease-of-use are critical considerations when designing isolated, regulated DC-DC converter systems for a broad range of robotics, UAV, rail, communications and defence\/aerospace applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/\" \/>\n<meta property=\"og:site_name\" content=\"Engineer News Network\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-11T10:00:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2019\/10\/V376-Image-DCM2322-pins-angled-large.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"3888\" \/>\n\t<meta property=\"og:image:height\" content=\"2592\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"headline\":\"Lower-power isolated, regulated DC-DC modules\",\"datePublished\":\"2019-10-11T10:00:21+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/\"},\"wordCount\":167,\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2019\\\/10\\\/V376-Image-DCM2322-pins-angled-large.jpg\",\"keywords\":[\"DCM2322\",\"isolated\",\"regulated DC-DC modules\",\"Vicor\"],\"articleSection\":[\"Electronics\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/\",\"name\":\"Lower-power isolated, regulated DC-DC modules - Engineer News Network\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2019\\\/10\\\/V376-Image-DCM2322-pins-angled-large.jpg\",\"datePublished\":\"2019-10-11T10:00:21+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"description\":\"Power density, low weight and ease-of-use are critical considerations when designing isolated, regulated DC-DC converter systems for a broad range of robotics, UAV, rail, communications and defence\\\/aerospace applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2019\\\/10\\\/V376-Image-DCM2322-pins-angled-large.jpg\",\"contentUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2019\\\/10\\\/V376-Image-DCM2322-pins-angled-large.jpg\",\"width\":3888,\"height\":2592,\"caption\":\"The new DCM2322 ChiP family, a lower-power variant of the Vicor DCM3623 series\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/lower-power-isolated-regulated-dc-dc-modules\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Lower-power isolated, regulated DC-DC modules\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\",\"name\":\"Engineer News Network\",\"description\":\"The ultimate online news and information resource for today's engineer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\",\"name\":\"admin\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lower-power isolated, regulated DC-DC modules - Engineer News Network","description":"Power density, low weight and ease-of-use are critical considerations when designing isolated, regulated DC-DC converter systems for a broad range of robotics, UAV, rail, communications and defence\/aerospace applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/","og_locale":"en_GB","og_type":"article","og_title":"Lower-power isolated, regulated DC-DC modules - Engineer News Network","og_description":"Power density, low weight and ease-of-use are critical considerations when designing isolated, regulated DC-DC converter systems for a broad range of robotics, UAV, rail, communications and defence\/aerospace applications.","og_url":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/","og_site_name":"Engineer News Network","article_published_time":"2019-10-11T10:00:21+00:00","og_image":[{"width":3888,"height":2592,"url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2019\/10\/V376-Image-DCM2322-pins-angled-large.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"1 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/#article","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/"},"author":{"name":"admin","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"headline":"Lower-power isolated, regulated DC-DC modules","datePublished":"2019-10-11T10:00:21+00:00","mainEntityOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/"},"wordCount":167,"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2019\/10\/V376-Image-DCM2322-pins-angled-large.jpg","keywords":["DCM2322","isolated","regulated DC-DC modules","Vicor"],"articleSection":["Electronics"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/","url":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/","name":"Lower-power isolated, regulated DC-DC modules - Engineer News Network","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/#primaryimage"},"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2019\/10\/V376-Image-DCM2322-pins-angled-large.jpg","datePublished":"2019-10-11T10:00:21+00:00","author":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"description":"Power density, low weight and ease-of-use are critical considerations when designing isolated, regulated DC-DC converter systems for a broad range of robotics, UAV, rail, communications and defence\/aerospace applications.","breadcrumb":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/#primaryimage","url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2019\/10\/V376-Image-DCM2322-pins-angled-large.jpg","contentUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2019\/10\/V376-Image-DCM2322-pins-angled-large.jpg","width":3888,"height":2592,"caption":"The new DCM2322 ChiP family, a lower-power variant of the Vicor DCM3623 series"},{"@type":"BreadcrumbList","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/lower-power-isolated-regulated-dc-dc-modules\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.engineernewsnetwork.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Lower-power isolated, regulated DC-DC modules"}]},{"@type":"WebSite","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website","url":"https:\/\/www.engineernewsnetwork.com\/blog\/","name":"Engineer News Network","description":"The ultimate online news and information resource for today's engineer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.engineernewsnetwork.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1","name":"admin","url":"https:\/\/www.engineernewsnetwork.com\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/14357","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/comments?post=14357"}],"version-history":[{"count":2,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/14357\/revisions"}],"predecessor-version":[{"id":14360,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/14357\/revisions\/14360"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media\/14358"}],"wp:attachment":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media?parent=14357"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/categories?post=14357"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/tags?post=14357"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}