{"id":22694,"date":"2022-08-10T10:10:10","date_gmt":"2022-08-10T09:10:10","guid":{"rendered":"https:\/\/www.engineernewsnetwork.com\/blog\/?p=22694"},"modified":"2022-08-10T10:10:11","modified_gmt":"2022-08-10T09:10:11","slug":"conduction-cooled-ac-dc-power-supplies","status":"publish","type":"post","link":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/","title":{"rendered":"Conduction-cooled AC-DC power supplies"},"content":{"rendered":"\n<p>TTI, Inc. \u2013 Europe is now stocking the <strong><a href=\"https:\/\/www.ttieurope.com\/content\/ttieurope\/en\/apps\/part-search.html?searchTerms=lcc1200&amp;systemsCatalog=&amp;x=true\" target=\"_blank\" rel=\"noreferrer noopener\">LCC1200 series of fully enclosed, conduction-cooled AC-DC power supplies<\/a><\/strong> from Advanced Energy. Rated at 1200W and boasting 93.5% efficiency, these power supplies incorporate a thermal baseplate and can deliver full output power over a wide operating temperature of -40\u00b0C to +85\u00b0C without derating. The target applications for the power supplies include telecommunications antenna and base station equipment, control consoles, and outdoor\/indoor signage. A constant current mode is also available for LED lighting and horticultural lighting applications.<\/p>\n\n\n\n<p>Housed in a robust metal case, the LCC1200 series is available with standard input\/output connectors or in fully sealed versions with integral cables that carry an IP65 rating against water or dust ingress. Their fanless operation also makes them suitable for environments where acoustic noise or dust disturbance would be an issue, such as in offices or medical facilities.<\/p>\n\n\n\n<p>Operating from a universal 90Vac to 264Vac input, the series can be used anywhere in the world without adjustment. Comprising four models, the LCC1200 series offers main output voltages of 24Vdc, 28Vdc, 36Vdc, and 48Vdc. The main output is adjustable across all models for maximum design flexibility, except the 28Vdc model. Each model also provides an additional 5Vdc standby output.&nbsp;<\/p>\n\n\n\n<p>Standard features include AC OK and DC OK signals, remote inhibit, and differential remote sense on the main output. The power supplies feature overtemperature and output overcurrent protection circuitry, with latching overvoltage protection of both the main and standby outputs. The LCC1200 series also supports active current sharing, allowing parallel connection of up to three units for high current applications.<\/p>\n\n\n\n<p>All models in the LCC1200 series come with a three-year warranty, are fully approved to the IEC 62368-1 ITE safety standard, and carry cUL, CE, UKCA, and CCC certifications. The built-in PMBus\u2122 interface provides flexible and comprehensive digital communication with control and monitoring functions for voltage, current, and temperature, as well as reporting of fault conditions.&nbsp;<\/p>\n\n\n\n<p>&#8220;With Advanced Energy&#8217;s LLC1200 series of conduction-cooled AC-DC power supplies, We&#8217;ve got the Power!&#8221; said Oskar Czechowski, Technical Development Manager for Power, TTI Europe. &#8220;While other power supplies require output derating above 55\u00b0C, the LCC1200 can maintain its full 1200W load capacity across a wide baseplate temperature at up to +85\u00b0C without forced air, reducing overall system cost. In addition, with its high power density of 15W\/in3, engineers save space in their end-application.&#8221;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>TTI, Inc. \u2013 Europe is now stocking the LCC1200 series of fully enclosed, conduction-cooled AC-DC power supplies from Advanced Energy. Rated at 1200W and boasting 93.5% efficiency, these power supplies incorporate a thermal baseplate and can deliver full output power over a wide operating temperature of -40\u00b0C to +85\u00b0C without derating. The target applications for &hellip;<\/p>\n","protected":false},"author":1,"featured_media":22695,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[107],"tags":[10629,10663,10664,10613],"class_list":["post-22694","post","type-post","status-publish","format-standard","has-post-thumbnail","","category-power","tag-advanced-energy","tag-fanless-ac-dc-power-supplies","tag-lcc1200-series","tag-tti-europe"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Conduction-cooled AC-DC power supplies - Engineer News Network<\/title>\n<meta name=\"description\" content=\"Maintains full 1200W load capacity across a wide -40\u00b0C to +85\u00b0C baseplate temperature without forced air cooling\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Conduction-cooled AC-DC power supplies - Engineer News Network\" \/>\n<meta property=\"og:description\" content=\"Maintains full 1200W load capacity across a wide -40\u00b0C to +85\u00b0C baseplate temperature without forced air cooling\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/\" \/>\n<meta property=\"og:site_name\" content=\"Engineer News Network\" \/>\n<meta property=\"article:published_time\" content=\"2022-08-10T09:10:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-10T09:10:11+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2022\/08\/LCC1200_duo3_300-min.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1772\" \/>\n\t<meta property=\"og:image:height\" content=\"1181\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"headline\":\"Conduction-cooled AC-DC power supplies\",\"datePublished\":\"2022-08-10T09:10:10+00:00\",\"dateModified\":\"2022-08-10T09:10:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/\"},\"wordCount\":400,\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/LCC1200_duo3_300-min.jpg\",\"keywords\":[\"Advanced Energy\",\"Fanless AC-DC Power Supplies\",\"LCC1200 Series\",\"TTI Europe\"],\"articleSection\":[\"Power\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/\",\"name\":\"Conduction-cooled AC-DC power supplies - Engineer News Network\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/LCC1200_duo3_300-min.jpg\",\"datePublished\":\"2022-08-10T09:10:10+00:00\",\"dateModified\":\"2022-08-10T09:10:11+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"description\":\"Maintains full 1200W load capacity across a wide -40\u00b0C to +85\u00b0C baseplate temperature without forced air cooling\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/LCC1200_duo3_300-min.jpg\",\"contentUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2022\\\/08\\\/LCC1200_duo3_300-min.jpg\",\"width\":1772,\"height\":1181,\"caption\":\"Advanced Energy's LCC1200 series of conduction-cooled AC-DC power supplies are now available from TTI Europe\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/conduction-cooled-ac-dc-power-supplies\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Conduction-cooled AC-DC power supplies\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\",\"name\":\"Engineer News Network\",\"description\":\"The ultimate online news and information resource for today's engineer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\",\"name\":\"admin\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Conduction-cooled AC-DC power supplies - Engineer News Network","description":"Maintains full 1200W load capacity across a wide -40\u00b0C to +85\u00b0C baseplate temperature without forced air cooling","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/","og_locale":"en_GB","og_type":"article","og_title":"Conduction-cooled AC-DC power supplies - Engineer News Network","og_description":"Maintains full 1200W load capacity across a wide -40\u00b0C to +85\u00b0C baseplate temperature without forced air cooling","og_url":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/","og_site_name":"Engineer News Network","article_published_time":"2022-08-10T09:10:10+00:00","article_modified_time":"2022-08-10T09:10:11+00:00","og_image":[{"width":1772,"height":1181,"url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2022\/08\/LCC1200_duo3_300-min.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/#article","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/"},"author":{"name":"admin","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"headline":"Conduction-cooled AC-DC power supplies","datePublished":"2022-08-10T09:10:10+00:00","dateModified":"2022-08-10T09:10:11+00:00","mainEntityOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/"},"wordCount":400,"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2022\/08\/LCC1200_duo3_300-min.jpg","keywords":["Advanced Energy","Fanless AC-DC Power Supplies","LCC1200 Series","TTI Europe"],"articleSection":["Power"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/","url":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/","name":"Conduction-cooled AC-DC power supplies - Engineer News Network","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/#primaryimage"},"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2022\/08\/LCC1200_duo3_300-min.jpg","datePublished":"2022-08-10T09:10:10+00:00","dateModified":"2022-08-10T09:10:11+00:00","author":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"description":"Maintains full 1200W load capacity across a wide -40\u00b0C to +85\u00b0C baseplate temperature without forced air cooling","breadcrumb":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/#primaryimage","url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2022\/08\/LCC1200_duo3_300-min.jpg","contentUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2022\/08\/LCC1200_duo3_300-min.jpg","width":1772,"height":1181,"caption":"Advanced Energy's LCC1200 series of conduction-cooled AC-DC power supplies are now available from TTI Europe"},{"@type":"BreadcrumbList","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/conduction-cooled-ac-dc-power-supplies\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.engineernewsnetwork.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Conduction-cooled AC-DC power supplies"}]},{"@type":"WebSite","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website","url":"https:\/\/www.engineernewsnetwork.com\/blog\/","name":"Engineer News Network","description":"The ultimate online news and information resource for today's engineer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.engineernewsnetwork.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1","name":"admin","url":"https:\/\/www.engineernewsnetwork.com\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/22694","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/comments?post=22694"}],"version-history":[{"count":1,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/22694\/revisions"}],"predecessor-version":[{"id":22696,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/22694\/revisions\/22696"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media\/22695"}],"wp:attachment":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media?parent=22694"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/categories?post=22694"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/tags?post=22694"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}