{"id":24506,"date":"2023-03-02T11:09:16","date_gmt":"2023-03-02T11:09:16","guid":{"rendered":"https:\/\/www.engineernewsnetwork.com\/blog\/?p=24506"},"modified":"2023-03-02T11:10:06","modified_gmt":"2023-03-02T11:10:06","slug":"sensor-measures-levels-precisely-in-tanks-and-open-vessels","status":"publish","type":"post","link":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/","title":{"rendered":"Sensor measures levels precisely in tanks and open vessels"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Non-contact level measurement for fluid media with an accuracy of \u00b12mm over a range of 0.01 to 10 m is offered by the new LW2120 radar level sensor from <strong><a href=\"https:\/\/www.ifm.com\/gb\/en\" target=\"_blank\" rel=\"noreferrer noopener\">ifm electronic<\/a><\/strong>. This sensor is equally suitable for use in closed tanks \u2013 either plastic or metal \u2013 or, with the addition of an accessory antenna, in open vessels such as sumps, chambers and Venturi flumes, where it can be incorporated in to a flow rate measurement system.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">LW2120 sensors use an FMCW radar signal at a frequency of 80 GHz to measure the level of the liquid medium and thus offer completely non-contact operation. This means they are not subject to wear and do not suffer from the build-up of contaminants. In addition, the performance and accuracy of the sensors are totally unaffected by the presence of steam, vapours or condensates. A further important benefit is that the radar signal can measure through plastic materials, so the sensors can be conveniently mounted above plastic tanks such as IBC containers or chemical storage tanks.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"499\" height=\"500\" src=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app.jpg\" alt=\"\" class=\"wp-image-24507\" srcset=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app.jpg 499w, https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app-300x300.jpg 300w, https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app-150x150.jpg 150w\" sizes=\"auto, (max-width: 499px) 100vw, 499px\" \/><\/a><figcaption class=\"wp-element-caption\">LW2120 sensors use an FMCW radar signal at a frequency of 80GHz to measure the level of the liquid medium<\/figcaption><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">For connections to the process control system, LW2120 sensors feature an IO-Link interface which ensures accurate data transmission even over long cables in electrically noisy environments. The IO-Link interface can also be used for remote parameterisation. To provide compatibility with conventional control systems, LW2120 sensors offer two further outputs which can optionally be configured as two switching outputs, for example to detect high and low level, or as one switching output and one 4-20 mA analogue output.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Non-contact level measurement for fluid media with an accuracy of \u00b12mm over a range of 0.01 to 10 m is offered by the new LW2120 radar level sensor from ifm electronic. This sensor is equally suitable for use in closed tanks \u2013 either plastic or metal \u2013 or, with the addition of an accessory antenna, &hellip;<\/p>\n","protected":false},"author":1,"featured_media":24507,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[104],"tags":[7720,9161,11380],"class_list":["post-24506","post","type-post","status-publish","format-standard","has-post-thumbnail","","category-electronics","tag-ifm","tag-level-measurement","tag-lw2120-sensors"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Sensor measures levels precisely in tanks and open vessels - Engineer News Network<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sensor measures levels precisely in tanks and open vessels - Engineer News Network\" \/>\n<meta property=\"og:description\" content=\"Non-contact level measurement for fluid media with an accuracy of \u00b12mm over a range of 0.01 to 10 m is offered by the new LW2120 radar level sensor from ifm electronic. This sensor is equally suitable for use in closed tanks \u2013 either plastic or metal \u2013 or, with the addition of an accessory antenna, &hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/\" \/>\n<meta property=\"og:site_name\" content=\"Engineer News Network\" \/>\n<meta property=\"article:published_time\" content=\"2023-03-02T11:09:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-03-02T11:10:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"499\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"headline\":\"Sensor measures levels precisely in tanks and open vessels\",\"datePublished\":\"2023-03-02T11:09:16+00:00\",\"dateModified\":\"2023-03-02T11:10:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/\"},\"wordCount\":274,\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/IFM088LW2120app.jpg\",\"keywords\":[\"ifm\",\"Level measurement\",\"LW2120 sensors\"],\"articleSection\":[\"Electronics\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/\",\"name\":\"Sensor measures levels precisely in tanks and open vessels - Engineer News Network\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/IFM088LW2120app.jpg\",\"datePublished\":\"2023-03-02T11:09:16+00:00\",\"dateModified\":\"2023-03-02T11:10:06+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/IFM088LW2120app.jpg\",\"contentUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2023\\\/03\\\/IFM088LW2120app.jpg\",\"width\":499,\"height\":500,\"caption\":\"LW2120 sensors use an FMCW radar signal at a frequency of 80GHz to measure the level of the liquid medium\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Sensor measures levels precisely in tanks and open vessels\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\",\"name\":\"Engineer News Network\",\"description\":\"The ultimate online news and information resource for today's engineer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\",\"name\":\"admin\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sensor measures levels precisely in tanks and open vessels - Engineer News Network","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/","og_locale":"en_GB","og_type":"article","og_title":"Sensor measures levels precisely in tanks and open vessels - Engineer News Network","og_description":"Non-contact level measurement for fluid media with an accuracy of \u00b12mm over a range of 0.01 to 10 m is offered by the new LW2120 radar level sensor from ifm electronic. This sensor is equally suitable for use in closed tanks \u2013 either plastic or metal \u2013 or, with the addition of an accessory antenna, &hellip;","og_url":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/","og_site_name":"Engineer News Network","article_published_time":"2023-03-02T11:09:16+00:00","article_modified_time":"2023-03-02T11:10:06+00:00","og_image":[{"width":499,"height":500,"url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/#article","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/"},"author":{"name":"admin","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"headline":"Sensor measures levels precisely in tanks and open vessels","datePublished":"2023-03-02T11:09:16+00:00","dateModified":"2023-03-02T11:10:06+00:00","mainEntityOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/"},"wordCount":274,"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app.jpg","keywords":["ifm","Level measurement","LW2120 sensors"],"articleSection":["Electronics"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/","url":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/","name":"Sensor measures levels precisely in tanks and open vessels - Engineer News Network","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/#primaryimage"},"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app.jpg","datePublished":"2023-03-02T11:09:16+00:00","dateModified":"2023-03-02T11:10:06+00:00","author":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"breadcrumb":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/#primaryimage","url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app.jpg","contentUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2023\/03\/IFM088LW2120app.jpg","width":499,"height":500,"caption":"LW2120 sensors use an FMCW radar signal at a frequency of 80GHz to measure the level of the liquid medium"},{"@type":"BreadcrumbList","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/sensor-measures-levels-precisely-in-tanks-and-open-vessels\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.engineernewsnetwork.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Sensor measures levels precisely in tanks and open vessels"}]},{"@type":"WebSite","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website","url":"https:\/\/www.engineernewsnetwork.com\/blog\/","name":"Engineer News Network","description":"The ultimate online news and information resource for today's engineer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.engineernewsnetwork.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1","name":"admin","url":"https:\/\/www.engineernewsnetwork.com\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/24506","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/comments?post=24506"}],"version-history":[{"count":2,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/24506\/revisions"}],"predecessor-version":[{"id":24509,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/24506\/revisions\/24509"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media\/24507"}],"wp:attachment":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media?parent=24506"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/categories?post=24506"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/tags?post=24506"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}