{"id":27943,"date":"2024-07-15T09:00:00","date_gmt":"2024-07-15T08:00:00","guid":{"rendered":"https:\/\/www.engineernewsnetwork.com\/blog\/?p=27943"},"modified":"2024-07-12T09:54:14","modified_gmt":"2024-07-12T08:54:14","slug":"wastewater-management-out-of-sight-not-out-of-mind","status":"publish","type":"post","link":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/","title":{"rendered":"Wastewater management: out of sight, not out of mind"},"content":{"rendered":"\n<p>Wastewater presents many challenges for the equipment that must collect and transport it to a treatment plant. These are compounded when the facilities are located in areas of high population density, where the additional debris that enters the sewerage system poses a significant threat to the reliable operation of the pumping equipment.<\/p>\n\n\n\n<p>Designing new airport terminals is a complex task and involves many engineering disciplines. While the flow of passengers and luggage are obvious areas for optimisation, the planning and design of equipment for managing wastewater and rainwater are equally important, even if they are less noticeable. <strong><a href=\"http:\/\/www.sulzer.com\" data-type=\"link\" data-id=\"www.sulzer.com\">Sulzer<\/a><\/strong> has applied its expertise to the new terminal under construction in Frankfurt, Germany, to ensure all the wastewater remains out of sight.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"2560\" src=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-scaled.jpg\" alt=\"\" class=\"wp-image-27946\" srcset=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-scaled.jpg 1920w, https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-225x300.jpg 225w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><\/a><figcaption class=\"wp-element-caption\">The Sanimat tank was customer designed for this application<\/figcaption><\/figure>\n<\/div>\n\n\n<p><strong>Planning ahead<\/strong><\/p>\n\n\n\n<p>In Frankfurt, a third airport terminal building and apron are under construction and the wastewater system will have to deal with both wastewater and the rainfall, which must be pumped to the local treatment works. Such a large infrastructure project requires considerable planning and Sulzer was brought in from an early stage to support the design and construction of the system to handle this.<\/p>\n\n\n\n<p>The new terminal will have a capacity up to 19 million passengers per year and Sulzer\u2019s expertise has helped to develop an efficient and effective solution for collecting and transporting the water for treatment. In all, 10 pumping stations for rainwater and one for wastewater will be installed, ready for passengers in 2026.<\/p>\n\n\n\n<p>Although, the drainage water from the apron should not cause any issues under normal circumstances, it is kept separate from the wastewater to avoid overloading the downstream station. If some of the water is contaminated by chemicals, such as jet fuel or fire suppressant foam, it can be diverted to the treatment works, rather than joining any stored rainwater.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><a href=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image005.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"907\" height=\"1024\" src=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image005-907x1024.jpg\" alt=\"\" class=\"wp-image-27945\" srcset=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image005-907x1024.jpg 907w, https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image005-266x300.jpg 266w, https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image005-768x867.jpg 768w, https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image005-1360x1536.jpg 1360w, https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image005-1814x2048.jpg 1814w\" sizes=\"auto, (max-width: 907px) 100vw, 907px\" \/><\/a><figcaption class=\"wp-element-caption\">The XFP pumps were mounted horizontally on sliding carriages in order to simplify maintenance<\/figcaption><\/figure>\n<\/div>\n\n\n<p><strong>Challenging waste<\/strong><\/p>\n\n\n\n<p>The waste that enters the system in airports is surprisingly diverse, including cleaning rags, items of clothing and nappies \u2013 all of which pose a significant challenge to any pump. Should a pump become blocked, it needs to be removed from service and cleared. In the meantime, the remaining pumps must cover the pumping demand until the blocked pump is returned to service.<\/p>\n\n\n\n<p>Experience from the pumping stations in Terminals 1 and 2 have highlighted concerns with debris in the wastewater flow that can cause pumps to stop working. Sulzer\u2019s suggestion was to add a Muffin Monster inline grinder, which would ensure continuous pump reliability and an extended service life.<\/p>\n\n\n\n<p>With prevention always better than cure, the installation of a grinder upstream of all the pumps can mitigate the downtime caused by debris in the system. Sulzer\u2019s Muffin Monster has proven its worth in many installations, resolving even the most challenging environments and will provide the same protection at Terminal 3.<\/p>\n\n\n\n<p><strong>Custom tanks<\/strong><\/p>\n\n\n\n<p>The wastewater will be collected in a Sanimat tank that was custom-designed for this application. The inflow will initially pass through the Muffin Monster grinder to ensure that any wipes or other debris from the terminal will not interfere with the reliable operation of the pumps.<\/p>\n\n\n\n<p>The Sanimat tanks can be specified with tank dimensions to suit the application and ensure that they can be transported through any access or doorways for installation. Applying Sulzer\u2019s design expertise to this project from the outset ensured that the location and capacity of the pumping stations could be optimised for efficiency and reliability.&nbsp;<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><a href=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image001-3-scaled.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1969\" src=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image001-3-scaled.jpg\" alt=\"\" class=\"wp-image-27944\" srcset=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image001-3-scaled.jpg 2560w, https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image001-3-300x231.jpg 300w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/a><figcaption class=\"wp-element-caption\">The Muffin monster inline grinder ensures continuous pump reliability and extended service life<\/figcaption><\/figure>\n<\/div>\n\n\n<p><strong>Rainwater engineering<\/strong><\/p>\n\n\n\n<p>For structural reasons, it was not possible to realise gravity drainage of the rainwater from the piers and the apron. For this reason, a total of 10 pumping stations of various designs were planned for rainwater and one for wastewater.<\/p>\n\n\n\n<p>The planned and constructed sewerage network on the site of the new Terminal 3 was not designed to absorb the rainwater produced. Through careful planning and prioritisation of the pumping stations, the rainwater is disposed of via the sewer network to avoid flooding of the apron.<\/p>\n\n\n\n<p>During the planning phase, care was also taken to use the same pump types wherever possible. This makes it possible to interchange the pumps in the pumping stations in the event of an emergency. This mainly affected the two largest pumping stations, which are responsible for the disposal of approximately 662 l\/s. Instead of two large pumps of type XFP501U-SK350, three pumps of type XFP351M-CH350 were planned and installed, making them identical to the pumps in another building.<\/p>\n\n\n\n<p><strong>Simplified maintenance<\/strong><\/p>\n\n\n\n<p>Planned maintenance is an important part of achieving pump availability as Robert Schumann, Sales Engineer, explains: \u201cOf course, pump reliability is crucial, so periodic maintenance is required to ensure ongoing performance. All the pumps have been installed horizontally in the dry wells, mounted on a sliding carriage, which provides a very simple procedure for disconnecting and removing the pump for inspection.\u201d<\/p>\n\n\n\n<p>In all, Sulzer has supplied 25 pumps from the XFP range as well as the custom Sanimat tanks and the Muffin Monster grinder. All of the pumps were delivered pre-assembled on the maintenance carriage for simple assembly and installation. Sulzer also constructed all of the pump control panels which have been delivered along with the pumps and grinder in a staged program to match the construction schedule.<\/p>\n\n\n\n<p>Robert continues: \u201cWe configured the pump controls to ensure that the downstream pumping station is not overwhelmed. To achieve this, we have carefully prioritised the pumps and coordinated the controls with the utility company to ensure optimum efficiency and capacity. All our hard work will be proven over the coming months, before the terminal opens in 2026.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Wastewater presents many challenges for the equipment that must collect and transport it to a treatment plant. These are compounded when the facilities are located in areas of high population density, where the additional debris that enters the sewerage system poses a significant threat to the reliable operation of the pumping equipment. Designing new airport &hellip;<\/p>\n","protected":false},"author":1,"featured_media":27946,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[199,1],"tags":[12955,12956,669,12957,108],"class_list":["post-27943","post","type-post","status-publish","format-standard","has-post-thumbnail","","category-news-views-and-opinion","category-process","tag-airside-water-management","tag-muffin-monster-grinder","tag-pumps","tag-sanimat-tanks","tag-sulzer"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Wastewater management: out of sight, not out of mind - Engineer News Network<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wastewater management: out of sight, not out of mind - Engineer News Network\" \/>\n<meta property=\"og:description\" content=\"Wastewater presents many challenges for the equipment that must collect and transport it to a treatment plant. These are compounded when the facilities are located in areas of high population density, where the additional debris that enters the sewerage system poses a significant threat to the reliable operation of the pumping equipment. Designing new airport &hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/\" \/>\n<meta property=\"og:site_name\" content=\"Engineer News Network\" \/>\n<meta property=\"article:published_time\" content=\"2024-07-15T08:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"2560\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"headline\":\"Wastewater management: out of sight, not out of mind\",\"datePublished\":\"2024-07-15T08:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/\"},\"wordCount\":957,\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/image004-scaled.jpg\",\"keywords\":[\"Airside water management\",\"Muffin Monster grinder\",\"pumps\",\"Sanimat tanks\",\"Sulzer\"],\"articleSection\":[\"News, Views and Opinion\",\"Process\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/\",\"name\":\"Wastewater management: out of sight, not out of mind - Engineer News Network\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/image004-scaled.jpg\",\"datePublished\":\"2024-07-15T08:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/image004-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/07\\\/image004-scaled.jpg\",\"width\":1920,\"height\":2560,\"caption\":\"The Sanimat tank was customer designed for this application\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wastewater-management-out-of-sight-not-out-of-mind\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wastewater management: out of sight, not out of mind\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\",\"name\":\"Engineer News Network\",\"description\":\"The ultimate online news and information resource for today's engineer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\",\"name\":\"admin\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Wastewater management: out of sight, not out of mind - Engineer News Network","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/","og_locale":"en_GB","og_type":"article","og_title":"Wastewater management: out of sight, not out of mind - Engineer News Network","og_description":"Wastewater presents many challenges for the equipment that must collect and transport it to a treatment plant. These are compounded when the facilities are located in areas of high population density, where the additional debris that enters the sewerage system poses a significant threat to the reliable operation of the pumping equipment. Designing new airport &hellip;","og_url":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/","og_site_name":"Engineer News Network","article_published_time":"2024-07-15T08:00:00+00:00","og_image":[{"width":1920,"height":2560,"url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-scaled.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/#article","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/"},"author":{"name":"admin","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"headline":"Wastewater management: out of sight, not out of mind","datePublished":"2024-07-15T08:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/"},"wordCount":957,"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-scaled.jpg","keywords":["Airside water management","Muffin Monster grinder","pumps","Sanimat tanks","Sulzer"],"articleSection":["News, Views and Opinion","Process"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/","url":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/","name":"Wastewater management: out of sight, not out of mind - Engineer News Network","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/#primaryimage"},"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-scaled.jpg","datePublished":"2024-07-15T08:00:00+00:00","author":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"breadcrumb":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/#primaryimage","url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-scaled.jpg","contentUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2024\/07\/image004-scaled.jpg","width":1920,"height":2560,"caption":"The Sanimat tank was customer designed for this application"},{"@type":"BreadcrumbList","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/wastewater-management-out-of-sight-not-out-of-mind\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.engineernewsnetwork.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Wastewater management: out of sight, not out of mind"}]},{"@type":"WebSite","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website","url":"https:\/\/www.engineernewsnetwork.com\/blog\/","name":"Engineer News Network","description":"The ultimate online news and information resource for today's engineer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.engineernewsnetwork.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1","name":"admin","url":"https:\/\/www.engineernewsnetwork.com\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/27943","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/comments?post=27943"}],"version-history":[{"count":2,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/27943\/revisions"}],"predecessor-version":[{"id":27948,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/27943\/revisions\/27948"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media\/27946"}],"wp:attachment":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media?parent=27943"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/categories?post=27943"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/tags?post=27943"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}