{"id":30903,"date":"2026-01-26T09:00:00","date_gmt":"2026-01-26T09:00:00","guid":{"rendered":"https:\/\/www.engineernewsnetwork.com\/blog\/?p=30903"},"modified":"2026-01-19T14:10:39","modified_gmt":"2026-01-19T14:10:39","slug":"three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors","status":"publish","type":"post","link":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/","title":{"rendered":"Three phase dv\/dt reactor improves reliability of drives and motors"},"content":{"rendered":"\n<p>The TPQDR3914\u00a0Three Phase dv\/dt Reactor from EMC solutions provider\u00a0<a href=\"https:\/\/emisglobal.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>EMIS<\/strong><\/a>\u00a0 is a specially designed inductor installed at the output of a Variable Frequency Drive (VFD) or inverter to limit the rate of voltage rise (dv\/dt) generated by PWM switching, reducing voltage stress and protecting motor insulation.<\/p>\n\n\n\n<p>Modern VFDs use fast IGBTs that can create high dv\/dt, voltage reflections (especially with long motor cables), increased bearing currents and EMI. Installation of a dv\/dt reactor helps prevent premature motor failure, nuisance power tripping and mitigates EMI.<\/p>\n\n\n\n<p>Designed for 0.8% impedance the reactor provides effective protection while causing a very low voltage drop and minimal power loss. The TPQDR3914 will operate reliably with modern high-frequency PWM drives, with current ratings from 4A to 500A. It reduces motor insulation stress, bearing currents, and the risk of premature motor failure while minimising\u00a0 reflected wave effects in long motor cables.<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Typical applications include<br>Variable Frequency Drives: dv\/dt reactors limit the voltage rise from PWM outputs protecting motors from insulation stress and reducing high frequency transients<\/li>\n\n\n\n<li>Pumps: smooth voltage transients from dv\/dt reactors prevent insulation and bearing damage in continuously running motors<\/li>\n\n\n\n<li>Fans and Blowers: Reduce motor voltage spikes and acoustic noise caused by fast switching in VFD driven fans and blowers<\/li>\n\n\n\n<li>Compressors: Mitigate high dv\/dt and reflected voltage peaks that can degrade motor windings under heavy mechanical load<\/li>\n\n\n\n<li>Conveyors: Protects conveyor motors from insulation stress during frequent starts\/stops and rapid speed changes<\/li>\n\n\n\n<li>HVAC Systems: Reduce electrical stress on motors in air-handling units, chillers and fans improving system reliability<\/li>\n\n\n\n<li>Long Motor Cables: Limit voltage overshoot and reflections that occur over extended cable runs protecting insulation and motor life<\/li>\n\n\n\n<li>Three-phase induction motors and old motors not designed for inverter duty.<\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>The TPQDR3914\u00a0Three Phase dv\/dt Reactor from EMC solutions provider\u00a0EMIS\u00a0 is a specially designed inductor installed at the output of a Variable Frequency Drive (VFD) or inverter to limit the rate of voltage rise (dv\/dt) generated by PWM switching, reducing voltage stress and protecting motor insulation. Modern VFDs use fast IGBTs that can create high dv\/dt, &hellip;<\/p>\n","protected":false},"author":1,"featured_media":30904,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[105],"tags":[12660,14263,14264],"class_list":["post-30903","post","type-post","status-publish","format-standard","has-post-thumbnail","","category-design","tag-emis","tag-tpqdr3914-three-phase-dv-dt-reactor","tag-variable-frequency-drive-vfd"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Three phase dv\/dt reactor improves reliability of drives and motors - Engineer News Network<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Three phase dv\/dt reactor improves reliability of drives and motors - Engineer News Network\" \/>\n<meta property=\"og:description\" content=\"The TPQDR3914\u00a0Three Phase dv\/dt Reactor from EMC solutions provider\u00a0EMIS\u00a0 is a specially designed inductor installed at the output of a Variable Frequency Drive (VFD) or inverter to limit the rate of voltage rise (dv\/dt) generated by PWM switching, reducing voltage stress and protecting motor insulation. Modern VFDs use fast IGBTs that can create high dv\/dt, &hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/\" \/>\n<meta property=\"og:site_name\" content=\"Engineer News Network\" \/>\n<meta property=\"article:published_time\" content=\"2026-01-26T09:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/01\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2300\" \/>\n\t<meta property=\"og:image:height\" content=\"2300\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"headline\":\"Three phase dv\\\/dt reactor improves reliability of drives and motors\",\"datePublished\":\"2026-01-26T09:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/\"},\"wordCount\":300,\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg\",\"keywords\":[\"EMIS\",\"TPQDR3914\u00a0Three Phase dv\\\/dt Reactor\",\"Variable Frequency Drive (VFD)\"],\"articleSection\":[\"Design\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/\",\"name\":\"Three phase dv\\\/dt reactor improves reliability of drives and motors - Engineer News Network\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg\",\"datePublished\":\"2026-01-26T09:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg\",\"contentUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/01\\\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg\",\"width\":2300,\"height\":2300,\"caption\":\"Provides protection to VFDs and inverters\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Three phase dv\\\/dt reactor improves reliability of drives and motors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\",\"name\":\"Engineer News Network\",\"description\":\"The ultimate online news and information resource for today's engineer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\",\"name\":\"admin\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Three phase dv\/dt reactor improves reliability of drives and motors - Engineer News Network","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/","og_locale":"en_GB","og_type":"article","og_title":"Three phase dv\/dt reactor improves reliability of drives and motors - Engineer News Network","og_description":"The TPQDR3914\u00a0Three Phase dv\/dt Reactor from EMC solutions provider\u00a0EMIS\u00a0 is a specially designed inductor installed at the output of a Variable Frequency Drive (VFD) or inverter to limit the rate of voltage rise (dv\/dt) generated by PWM switching, reducing voltage stress and protecting motor insulation. Modern VFDs use fast IGBTs that can create high dv\/dt, &hellip;","og_url":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/","og_site_name":"Engineer News Network","article_published_time":"2026-01-26T09:00:00+00:00","og_image":[{"width":2300,"height":2300,"url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/01\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/#article","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/"},"author":{"name":"admin","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"headline":"Three phase dv\/dt reactor improves reliability of drives and motors","datePublished":"2026-01-26T09:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/"},"wordCount":300,"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/01\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg","keywords":["EMIS","TPQDR3914\u00a0Three Phase dv\/dt Reactor","Variable Frequency Drive (VFD)"],"articleSection":["Design"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/","url":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/","name":"Three phase dv\/dt reactor improves reliability of drives and motors - Engineer News Network","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/#primaryimage"},"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/01\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg","datePublished":"2026-01-26T09:00:00+00:00","author":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"breadcrumb":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/#primaryimage","url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/01\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg","contentUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/01\/2426-PR1\u2013-TPQDR3914-Three-Phase-dv-dt-Reactor-from-EMIS.jpg","width":2300,"height":2300,"caption":"Provides protection to VFDs and inverters"},{"@type":"BreadcrumbList","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/three-phase-dv-dt-reactor-improves-reliability-of-drives-and-motors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.engineernewsnetwork.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Three phase dv\/dt reactor improves reliability of drives and motors"}]},{"@type":"WebSite","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website","url":"https:\/\/www.engineernewsnetwork.com\/blog\/","name":"Engineer News Network","description":"The ultimate online news and information resource for today's engineer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.engineernewsnetwork.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1","name":"admin","url":"https:\/\/www.engineernewsnetwork.com\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/30903","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/comments?post=30903"}],"version-history":[{"count":2,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/30903\/revisions"}],"predecessor-version":[{"id":30906,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/30903\/revisions\/30906"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media\/30904"}],"wp:attachment":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media?parent=30903"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/categories?post=30903"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/tags?post=30903"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}