{"id":33866,"date":"2026-09-29T09:00:00","date_gmt":"2026-09-29T08:00:00","guid":{"rendered":"https:\/\/www.engineernewsnetwork.com\/blog\/?p=33866"},"modified":"2026-09-24T18:12:32","modified_gmt":"2026-09-24T17:12:32","slug":"65v-digital-power-monitors-help-designers-track-accumulated-energy-data","status":"publish","type":"post","link":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/","title":{"rendered":"65V digital power monitors help designers track accumulated energy data"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">As automotive, AI\/data centre, networking and industrial systems quickly migrate toward 48V power architectures to improve efficiency and support higher power demands, designers need more than visibility into instantaneous voltage and current conditions. They need systems that understand energy use over time and can respond intelligently to changing power conditions. <\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Microchip Technology announces the <a href=\"https:\/\/www.microchip.com\/en-us\/products\/amplifiers-and-linear-ics\/current-voltage-power-monitor-ics\"><strong>PAC1761 and PAC1861<\/strong><\/a> families of 65V energy-aware digital power monitors that combine accumulated power-measurement insights with the necessary high-voltage measurement headroom and transient spike protection capabilities to help make 48V power architectures more efficient and resilient.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The move to 48V power architectures demands that digital power monitors have an additional operational margin of up-to-65V measurement and 75V of spike protection to ensure transient survivability. The PAC1761 and PAC1861 devices add to these capabilities the intelligence to understand and react in real time to energy usage dynamics based on accumulated power measurement data.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u201cThe industry conversation is shifting from measuring power at a single point in time to understanding and responding to energy behavior across an entire system and its lifecycle,\u201d said Keith Pazul, vice president of Microchip\u2019s mixed-signal linear business unit. \u201cThe PAC1761 and PAC1861 families are designed to help customers build better performing and more reliable 48V systems that can measure instantaneous conditions and understand energy consumption and availability over time. These scalable, low-power solutions reduce monitoring overhead and include pin-compatible package options that improve source flexibility while reducing design risk.\u201d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Microchip\u2019s digital power monitoring devices feature programmable alerts for voltage, current and power excursions, step-limit detection to identify sudden load changes, and configurable accumulated-energy thresholds that enable proactive system management based on both instantaneous and long-term power behaviour.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Target applications include automotive, AI\/data centre, networking, industrial, server, telecom\/Power over Ethernet (PoE) and 48V power distribution systems. The 12-bit PAC1761 and 16-bit PAC1861 options are available in VDFN-8 (similar to SOT23-8), VDFN-10 and MSOP-10 packages including automotive-orderable variants. Pin-compatible options can reduce redesign risk, shorten qualification cycles and give customers flexibility to move between devices as requirements, availability, cost or performance change.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>As automotive, AI\/data centre, networking and industrial systems quickly migrate toward 48V power architectures to improve efficiency and support higher power demands, designers need more than visibility into instantaneous voltage and current conditions. They need systems that understand energy use over time and can respond intelligently to changing power conditions. Microchip Technology announces the PAC1761 &hellip;<\/p>\n","protected":false},"author":1,"featured_media":33867,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[104],"tags":[169,15634],"class_list":["post-33866","post","type-post","status-publish","format-standard","has-post-thumbnail","","category-electronics","tag-microchip","tag-pac1761-and-pac1861"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>65V digital power monitors help designers track accumulated energy data - Engineer News Network<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/\" \/>\n<meta property=\"og:locale\" content=\"en_GB\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"65V digital power monitors help designers track accumulated energy data - Engineer News Network\" \/>\n<meta property=\"og:description\" content=\"As automotive, AI\/data centre, networking and industrial systems quickly migrate toward 48V power architectures to improve efficiency and support higher power demands, designers need more than visibility into instantaneous voltage and current conditions. They need systems that understand energy use over time and can respond intelligently to changing power conditions. Microchip Technology announces the PAC1761 &hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/\" \/>\n<meta property=\"og:site_name\" content=\"Engineer News Network\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-29T08:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/09\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1422\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimated reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"headline\":\"65V digital power monitors help designers track accumulated energy data\",\"datePublished\":\"2026-09-29T08:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/\"},\"wordCount\":354,\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg\",\"keywords\":[\"Microchip\",\"PAC1761 and PAC1861\"],\"articleSection\":[\"Electronics\"],\"inLanguage\":\"en-GB\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/\",\"name\":\"65V digital power monitors help designers track accumulated energy data - Engineer News Network\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg\",\"datePublished\":\"2026-09-29T08:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/#breadcrumb\"},\"inLanguage\":\"en-GB\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-GB\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg\",\"width\":2560,\"height\":1422,\"caption\":\"Improves system response in applications that also depend on higher levels of measurement headroom and spike protection\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"65V digital power monitors help designers track accumulated energy data\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/\",\"name\":\"Engineer News Network\",\"description\":\"The ultimate online news and information resource for today&#039;s engineer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-GB\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/#\\\/schema\\\/person\\\/4477342aea8e299c6a21761e513ea8e1\",\"name\":\"admin\",\"url\":\"https:\\\/\\\/www.engineernewsnetwork.com\\\/blog\\\/author\\\/admin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"65V digital power monitors help designers track accumulated energy data - Engineer News Network","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/","og_locale":"en_GB","og_type":"article","og_title":"65V digital power monitors help designers track accumulated energy data - Engineer News Network","og_description":"As automotive, AI\/data centre, networking and industrial systems quickly migrate toward 48V power architectures to improve efficiency and support higher power demands, designers need more than visibility into instantaneous voltage and current conditions. They need systems that understand energy use over time and can respond intelligently to changing power conditions. Microchip Technology announces the PAC1761 &hellip;","og_url":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/","og_site_name":"Engineer News Network","article_published_time":"2026-09-29T08:00:00+00:00","og_image":[{"width":2560,"height":1422,"url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/09\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg","type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Estimated reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/#article","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/"},"author":{"name":"admin","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"headline":"65V digital power monitors help designers track accumulated energy data","datePublished":"2026-09-29T08:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/"},"wordCount":354,"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/09\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg","keywords":["Microchip","PAC1761 and PAC1861"],"articleSection":["Electronics"],"inLanguage":"en-GB"},{"@type":"WebPage","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/","url":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/","name":"65V digital power monitors help designers track accumulated energy data - Engineer News Network","isPartOf":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/#primaryimage"},"image":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/#primaryimage"},"thumbnailUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/09\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg","datePublished":"2026-09-29T08:00:00+00:00","author":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1"},"breadcrumb":{"@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/#breadcrumb"},"inLanguage":"en-GB","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/"]}]},{"@type":"ImageObject","inLanguage":"en-GB","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/#primaryimage","url":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/09\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg","contentUrl":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-content\/uploads\/2026\/09\/MC1783-Image-PAC1761-PAC1861-GRAPH-scaled.jpg","width":2560,"height":1422,"caption":"Improves system response in applications that also depend on higher levels of measurement headroom and spike protection"},{"@type":"BreadcrumbList","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/65v-digital-power-monitors-help-designers-track-accumulated-energy-data\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.engineernewsnetwork.com\/blog\/"},{"@type":"ListItem","position":2,"name":"65V digital power monitors help designers track accumulated energy data"}]},{"@type":"WebSite","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#website","url":"https:\/\/www.engineernewsnetwork.com\/blog\/","name":"Engineer News Network","description":"The ultimate online news and information resource for today&#039;s engineer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.engineernewsnetwork.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-GB"},{"@type":"Person","@id":"https:\/\/www.engineernewsnetwork.com\/blog\/#\/schema\/person\/4477342aea8e299c6a21761e513ea8e1","name":"admin","url":"https:\/\/www.engineernewsnetwork.com\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/33866","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/comments?post=33866"}],"version-history":[{"count":1,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/33866\/revisions"}],"predecessor-version":[{"id":33868,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/posts\/33866\/revisions\/33868"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media\/33867"}],"wp:attachment":[{"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/media?parent=33866"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/categories?post=33866"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.engineernewsnetwork.com\/blog\/wp-json\/wp\/v2\/tags?post=33866"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}