Home / Electronics / No interruption of critical loads 
when transferring between utility and generator sources

No interruption of critical loads 
when transferring between utility and generator sources

System offers users soft loading transfer and phase lock synchronising

Russelectric, a manufacturer of automatic transfer switches and power control systems, offers its Utility Paralleling System, for ensuring that critical loads experience no interruption when transferring between live utility and generator sources.

The system can also be configured for peak shaving, utility-sponsored load curtailment programs, exporting power to the grid, and for a variety of combined heat and power (CHP) applications.



The Russelectric Utility Paralleling System has been used by hospitals, data centres, telecommunications, and banking facilities, as well as airports, water and waste water, and renewable energy facilities.

Russelectric paralleling systems incorporate dual, redundant, hot synchronised programmable logic controllers (PLCs) for system control.
Discrete switches, meters, and control devices are standard to allow manual control capability in the event that both system PLCs fail.

With the Russelectric Utility Paralleling System, users get soft loading transfer and phase lock synchronising when paralleling with the utility, which reduces transients and controls the loading to the engine generators.

All paralleling systems are UL listed. Selector switches are provided for open/closed transition, automatic/manual paralleling of generators and utility sources, and automatic/manual retransfer between both sources of power.

The Utility Paralleling System offers a choice of either momentary paralleling with the utility or sustained paralleling for soft loading.

Also available is paralleling of generator sets with the utility upon return of the utility source after power interruption.

System operation begins with testing in closed-transition mode with no interruption of the load.

Generators are then paralleled with the utility and the load is transferred to them. Upon completion of testing, the load is retransferred through closed-transition to the utility source without disturbance.

Check Also

Mobile ultrasonic sensor

Ifm has unveiled the SU Puresonic Mobile Ultrasonic Sensor. Designed for measurement precision and durability, this …

Automotive surge-protection Zener diodes in compact SOD-523 package

Toshiba expands its automotive-grade surge-protection Zener diode lineup with the launch of the XCEZ series. These …

Application-specific MOSFETs provide enhanced dynamic current sharing for high power industrial applications

Nexperia introduces the latest additions to its portfolio of application-specific MOSFETs (ASFETs), whose features have …